There is a quality control data sheet as follows,
You can follow this process to check the refrigerator quality while installation.
| Process Name | Technical Requirements | Self-Inspection | Mutual Inspection | Qualified | Inspector | Operator Signature |
| Assembly | All components are firmly fixed with appropriate clearances and neat appearance; feet are securely installed, and inner liner is positioned correctly. | |||||
| Door Installation | Qualified door body shall be installed without deformation, with good sealing, and clearances between doors meet requirements; hinges are firmly and properly installed; cross and vertical beams are in place without protrusion. | |||||
| Compressor & Condenser Installation | Compressor accessories must conform to the requirements of the corresponding machine, and all components are firmly installed; fixed securely, and limit sleeves and spring washers must not be missing for bolt-fastened parts. | |||||
| Pipe Connection | Each pipe insertion depth complies with process requirements; pipes must not be dead-bent, with a bending radius not less than R28 mm; pipes shall not collide, rub, cross, or wind with each other. | |||||
| Electrical Installation | Control panel is firmly installed with correct wiring and no looseness; all power cords shall not be too close to the outer shell, and connecting wires are laid out reasonably. | |||||
| Welding | Weld points are smooth and full, with no undercut, incomplete penetration, sand holes, or leakage allowed. | |||||
| Nitrogen Charge & Leak Test | The refrigeration system is charged with 1.6 MPa nitrogen, and no leakage is allowed at any weld point. | |||||
| Vacuum Pumping | Vacuum pumping time shall be no less than 30 minutes, and the system vacuum degree shall be below -1 Pa. | |||||
| Refrigerant Charging | Charge refrigerant according to the dosage specified in the process, with a charging accuracy of ±0.5g. Weld points are smooth and full without leakage. | |||||
| Electrical Performance | Grounding resistance ≤ 0.1 Ω (Actual measurement) Leakage current ≤ 3.5 mA (Actual measurement) Electric strength: 1800V/1s (Actual measurement) Insulation resistance ≥ 50 MΩ (Actual measurement) | |||||
| Leakage Inspection | Refrigerant leakage ≤ 0.5g/year (Actual measurement) | |||||
| Refrigeration Performance | Standard requirements: Ambient temperature 38℃ Test time: 1 hour Temperature standard: 13℃ Refrigerating temperature / Freezing temperature | |||||
| Sanitation Cleaning | No foam, adhesive residue, or glue stains inside and outside the cabinet and at joints. | |||||
| Final Inspection | Execute in accordance with specified regulations. | |||||
| Packaging | Complete packaging with correct identification. | |||||
| Warehouse Entry Date | ||||||
| Note: | Mark "√" for qualified items in blank columns and "×" for defective items; for items marked "×" | fill in the return work order on the reverse side." |





For more commercial refrigerator information, please kindly contact us:
Leo Wang
Export manager
For commercial refrigerators, showcase display coolers, supermarket display freezers, Kitchen appliance
Recently Posted
-
One bathtub making factory use our resin spray gun with fiber chopper.
September 21, 2026One bathtub making factory use our resin spray gun with fiber chopper.The resin spray gun have these components as follows,1.
Read More -
Acrylic Bathtub Making Machines and Molds for our Saudi Arabia Customer
September 20, 2026Acrylic Bathtub Making Machines and Molds for our Saudi Arabia CustomerWe arrange the bathtub making line and the devices as follo
Read More -
How to make a good acrylic bathtub
March 20, 2026Product DescriptionFirst step: prepare for the making machines and moldsThe acrylic bathtub making need the devices as follows,&nb
Read More -
How many kinds of commercial refreigerators
March 13, 2026How many kinds of commercial refreigerators?The commercial refreigerators are as follows,Commercial Kitchen RefrigeratorsChes
Read More